Autovalves

Autovalve arresters for electrical networks generally consist of an arc gap pile comprising a series of arc gaps connected in series with a resistance. This resistance now generally is made of a material changing its resistance when the voltage changes, in the following called voltage sensitive resistance.


These conductors are bonded to earth either through the metal structure of a pole or tower, or by additional ground electrodes installed at regular intervals along the line. As a general rule, overhead power lines with voltages below 50 kV do not have a "static" conductor, but most lines carrying more than 50 kV do. The ground conductor cable may also support fibre optic cables for data transmission.
In some instances, these conductors are insulated from direct bonding with earth and may be used as low voltage communication lines. If the voltage exceeds a certain threshold, such as during a lightning termination to the conductor, it "jumps" the insulators and passes to earth.
Protection of electrical substations is as varied as lightning rods themselves, and is often proprietary to the electric company.




Dampers Stockbridge: Summing in the air powerlines resonant vibrations as a result of wind can increase the amplitude of vibration coming to break the cables, to prevent this event there are various techniques, one of which is through the dampers we see occur in pictures. The damper absorbs energy continuously vibration lines by wind and thus prevents the amplitude of the wave is developed on another occasion I will explain this effect more specifically.

Insulator string: insulators are electrically separated conductor support, depending on the voltage line will be roughly insulators, the larger chain greater is the voltage insulators. In the picture we can see that the insulator string carry a kind of horns that are overvoltage protection, this is because in the event of an overvoltage on the line if this was very large insulator could explode, but having this protection outside the arc jump insulator protecting it.


Counterweights: They are usually hot galvanized iron and built circular or rectangular, as the name suggests is used for the insulator string has extra weight to the wind or other weather events not approach leads to lattice tower because if this happens produce earth faults, short circuits, etc.





Thread guards or protective conductor: The ground wire is connected to the highest point of the support and connected between supports (each bearing in turn is connected to ground), has several functions: Reduce stress induced in the airline by lightning strikes in the vicinity, protecting the phase conductors absorbing atmospheric discharges, reduce the action of lightning downloaded directly to the airline. In some installations these cables inside an optical fiber to transport telecommunications signals between substations installed. If you look at the threads guard Stockbridge dampers are also installed.


Grounding: The supports are grounded through plates, spades, or buried cables or a mixture of them all, everything depends on the terrain, etc. However all supports must have a connection that can be disconnected pikes ground support, especially for measuring earth resistance.


Arresters

In other entries and we try the line surge protection. I put classical and surge protection that begins to use, automatic valves, such as those shown in photographs.


classic surge protection, its technical name is "exploders" but also slang are called the "horns". The central rod is called in bird rod.